Intel(R) Dynamic Platform and Thermal Framework Sysfs Interface¶
- Copyright:
© 2022 Intel Corporation
- Author:
Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Introduction¶
Intel(R) Dynamic Platform and Thermal Framework (DPTF) is a platform level hardware/software solution for power and thermal management.
As a container for multiple power/thermal technologies, DPTF provides a coordinated approach for different policies to effect the hardware state of a system.
Since it is a platform level framework, this has several components. Some parts of the technology is implemented in the firmware and uses ACPI and PCI devices to expose various features for monitoring and control. Linux has a set of kernel drivers exposing hardware interface to user space. This allows user space thermal solutions like “Linux Thermal Daemon” to read platform specific thermal and power tables to deliver adequate performance while keeping the system under thermal limits.
DPTF ACPI Drivers interface¶
/sys/bus/platform/devices/<N>/uuids
, where <N>
=INT3400|INTC1040|INTC1041|INTC10A0
available_uuids
(RO)A set of UUIDs strings presenting available policies which should be notified to the firmware when the user space can support those policies.
UUID strings:
“42A441D6-AE6A-462b-A84B-4A8CE79027D3” : Passive 1
“3A95C389-E4B8-4629-A526-C52C88626BAE” : Active
“97C68AE7-15FA-499c-B8C9-5DA81D606E0A” : Critical
“63BE270F-1C11-48FD-A6F7-3AF253FF3E2D” : Adaptive performance
“5349962F-71E6-431D-9AE8-0A635B710AEE” : Emergency call
“9E04115A-AE87-4D1C-9500-0F3E340BFE75” : Passive 2
“F5A35014-C209-46A4-993A-EB56DE7530A1” : Power Boss
“6ED722A7-9240-48A5-B479-31EEF723D7CF” : Virtual Sensor
“16CAF1B7-DD38-40ED-B1C1-1B8A1913D531” : Cooling mode
“BE84BABF-C4D4-403D-B495-3128FD44dAC1” : HDC
current_uuid
(RW)User space can write strings from available UUIDs, one at a time.
/sys/bus/platform/devices/<N>/
, where <N>
=INT3400|INTC1040|INTC1041|INTC10A0
imok
(WO)User space daemon write 1 to respond to firmware event for sending keep alive notification. User space receives THERMAL_EVENT_KEEP_ALIVE kobject uevent notification when firmware calls for user space to respond with imok ACPI method.
odvp*
(RO)Firmware thermal status variable values. Thermal tables calls for different processing based on these variable values.
data_vault
(RO)Binary thermal table. Refer to https:/github.com/intel/thermal_daemon for decoding thermal table.
production_mode
(RO)When different from zero, manufacturer locked thermal configuration from further changes.
ACPI Thermal Relationship table interface¶
/dev/acpi_thermal_rel
This device provides IOCTL interface to read standard ACPI thermal relationship tables via ACPI methods _TRT and _ART. These IOCTLs are defined in drivers/thermal/intel/int340x_thermal/acpi_thermal_rel.h
IOCTLs:
ACPI_THERMAL_GET_TRT_LEN: Get length of TRT table
ACPI_THERMAL_GET_ART_LEN: Get length of ART table
ACPI_THERMAL_GET_TRT_COUNT: Number of records in TRT table
ACPI_THERMAL_GET_ART_COUNT: Number of records in ART table
ACPI_THERMAL_GET_TRT: Read binary TRT table, length to read is provided via argument to ioctl().
ACPI_THERMAL_GET_ART: Read binary ART table, length to read is provided via argument to ioctl().
DPTF ACPI Sensor drivers¶
DPTF Sensor drivers are presented as standard thermal sysfs thermal_zone.
DPTF ACPI Cooling drivers¶
DPTF cooling drivers are presented as standard thermal sysfs cooling_device.
DPTF Processor thermal PCI Driver interface¶
/sys/bus/pci/devices/0000:00:04.0/power_limits/
Refer to Power Capping Framework for powercap ABI.
power_limit_0_max_uw
(RO)Maximum powercap sysfs constraint_0_power_limit_uw for Intel RAPL
power_limit_0_step_uw
(RO)Power limit increment/decrements for Intel RAPL constraint 0 power limit
power_limit_0_min_uw
(RO)Minimum powercap sysfs constraint_0_power_limit_uw for Intel RAPL
power_limit_0_tmin_us
(RO)Minimum powercap sysfs constraint_0_time_window_us for Intel RAPL
power_limit_0_tmax_us
(RO)Maximum powercap sysfs constraint_0_time_window_us for Intel RAPL
power_limit_1_max_uw
(RO)Maximum powercap sysfs constraint_1_power_limit_uw for Intel RAPL
power_limit_1_step_uw
(RO)Power limit increment/decrements for Intel RAPL constraint 1 power limit
power_limit_1_min_uw
(RO)Minimum powercap sysfs constraint_1_power_limit_uw for Intel RAPL
power_limit_1_tmin_us
(RO)Minimum powercap sysfs constraint_1_time_window_us for Intel RAPL
power_limit_1_tmax_us
(RO)Maximum powercap sysfs constraint_1_time_window_us for Intel RAPL
power_floor_status
(RO)When set to 1, the power floor of the system in the current configuration has been reached. It needs to be reconfigured to allow power to be reduced any further.
power_floor_enable
(RW)When set to 1, enable reading and notification of the power floor status. Notifications are triggered for the power_floor_status attribute value changes.
/sys/bus/pci/devices/0000:00:04.0/
tcc_offset_degree_celsius
(RW)TCC offset from the critical temperature where hardware will throttle CPU.
/sys/bus/pci/devices/0000:00:04.0/workload_request
workload_available_types
(RO)Available workload types. User space can specify one of the workload type it is currently executing via workload_type. For example: idle, bursty, sustained etc.
workload_type
(RW)User space can specify any one of the available workload type using this interface.
DPTF Processor thermal RFIM interface¶
RFIM interface allows adjustment of FIVR (Fully Integrated Voltage Regulator), DDR (Double Data Rate) and DLVR (Digital Linear Voltage Regulator) frequencies to avoid RF interference with WiFi and 5G.
Switching voltage regulators (VR) generate radiated EMI or RFI at the fundamental frequency and its harmonics. Some harmonics may interfere with very sensitive wireless receivers such as Wi-Fi and cellular that are integrated into host systems like notebook PCs. One of mitigation methods is requesting SOC integrated VR (IVR) switching frequency to a small % and shift away the switching noise harmonic interference from radio channels. OEM or ODMs can use the driver to control SOC IVR operation within the range where it does not impact IVR performance.
Some products use DLVR instead of FIVR as switching voltage regulator. In this case attributes of DLVR must be adjusted instead of FIVR.
While shifting the frequencies additional clock noise can be introduced, which is compensated by adjusting Spread spectrum percent. This helps to reduce the clock noise to meet regulatory compliance. This spreading % increases bandwidth of signal transmission and hence reduces the effects of interference, noise and signal fading.
DRAM devices of DDR IO interface and their power plane can generate EMI at the data rates. Similar to IVR control mechanism, Intel offers a mechanism by which DDR data rates can be changed if several conditions are met: there is strong RFI interference because of DDR; CPU power management has no other restriction in changing DDR data rates; PC ODMs enable this feature (real time DDR RFI Mitigation referred to as DDR-RFIM) for Wi-Fi from BIOS.
FIVR attributes
/sys/bus/pci/devices/0000:00:04.0/fivr/
vco_ref_code_lo
(RW)The VCO reference code is an 11-bit field and controls the FIVR switching frequency. This is the 3-bit LSB field.
vco_ref_code_hi
(RW)The VCO reference code is an 11-bit field and controls the FIVR switching frequency. This is the 8-bit MSB field.
spread_spectrum_pct
(RW)Set the FIVR spread spectrum clocking percentage
spread_spectrum_clk_enable
(RW)Enable/disable of the FIVR spread spectrum clocking feature
rfi_vco_ref_code
(RW)This field is a read only status register which reflects the current FIVR switching frequency
fivr_fffc_rev
(RW)This field indicated the revision of the FIVR HW.
DVFS attributes
/sys/bus/pci/devices/0000:00:04.0/dvfs/
rfi_restriction_run_busy
(RW)Request the restriction of specific DDR data rate and set this value 1. Self reset to 0 after operation.
rfi_restriction_err_code
(RW)0 :Request is accepted, 1:Feature disabled, 2: the request restricts more points than it is allowed
rfi_restriction_data_rate_Delta
(RW)Restricted DDR data rate for RFI protection: Lower Limit
rfi_restriction_data_rate_Base
(RW)Restricted DDR data rate for RFI protection: Upper Limit
ddr_data_rate_point_0
(RO)DDR data rate selection 1st point
ddr_data_rate_point_1
(RO)DDR data rate selection 2nd point
ddr_data_rate_point_2
(RO)DDR data rate selection 3rd point
ddr_data_rate_point_3
(RO)DDR data rate selection 4th point
rfi_disable (RW)
Disable DDR rate change feature
DLVR attributes
/sys/bus/pci/devices/0000:00:04.0/dlvr/
dlvr_hardware_rev
(RO)DLVR hardware revision.
dlvr_freq_mhz
(RO)Current DLVR PLL frequency in MHz.
dlvr_freq_select
(RW)Sets DLVR PLL clock frequency. Once set, and enabled via dlvr_rfim_enable, the dlvr_freq_mhz will show the current DLVR PLL frequency.
dlvr_pll_busy
(RO)PLL can’t accept frequency change when set.
dlvr_rfim_enable
(RW)0: Disable RF frequency hopping, 1: Enable RF frequency hopping.
dlvr_spread_spectrum_pct
(RW)Sets DLVR spread spectrum percent value.
dlvr_control_mode
(RW)Specifies how frequencies are spread using spread spectrum. 0: Down spread, 1: Spread in the Center.
dlvr_control_lock
(RW)1: future writes are ignored.
DPTF Power supply and Battery Interface¶
Refer to Documentation/ABI/testing/sysfs-platform-dptf
DPTF Fan Control¶
Refer to ACPI Fan Performance States
Workload Type Hints¶
The firmware in Meteor Lake processor generation is capable of identifying workload type and passing hints regarding it to the OS. A special sysfs interface is provided to allow user space to obtain workload type hints from the firmware and control the rate at which they are provided.
User space can poll attribute “workload_type_index” for the current hint or can receive a notification whenever the value of this attribute is updated.
file:/sys/bus/pci/devices/0000:00:04.0/workload_hint/ Segment 0, bus 0, device 4, function 0 is reserved for the processor thermal device on all Intel client processors. So, the above path doesn’t change based on the processor generation.
workload_hint_enable
(RW)Enable firmware to send workload type hints to user space.
notification_delay_ms
(RW)Minimum delay in milliseconds before firmware will notify OS. This is for the rate control of notifications. This delay is between changing the workload type prediction in the firmware and notifying the OS about the change. The default delay is 1024 ms. The delay of 0 is invalid. The delay is rounded up to the nearest power of 2 to simplify firmware programming of the delay value. The read of notification_delay_ms attribute shows the effective value used.
workload_type_index
(RO)Predicted workload type index. User space can get notification of change via existing sysfs attribute change notification mechanism.
The supported index values and their meaning for the Meteor Lake processor generation are as follows:
- 0 - Idle: System performs no tasks, power and idle residency are
consistently low for long periods of time.
- 1 – Battery Life: Power is relatively low, but the processor may
still be actively performing a task, such as video playback for a long period of time.
- 2 – Sustained: Power level that is relatively high for a long period
of time, with very few to no periods of idleness, which will eventually exhaust RAPL Power Limit 1 and 2.
- 3 – Bursty: Consumes a relatively constant average amount of power, but
periods of relative idleness are interrupted by bursts of activity. The bursts are relatively short and the periods of relative idleness between them typically prevent RAPL Power Limit 1 from being exhausted.
4 – Unknown: Can’t classify.